Circumferential silicone sponge scleral buckling induced axial length changes: case series and comparison to literature

Abstract

Background

This study compared axial length changes induced by circumferential scleral buckling using a silicone sponge with literature reports for solid silicone rubber.

Methods

Records of patients treated with scleral buckling in 2009–2013 using a silicone sponge, with preoperative axial length biometry measurements were reviewed. Additional information included age, type of surgery, additional surgeries, phakic status and anatomical success of reattachment. Patients underwent repeat biometry. The medical literature was reviewed for articles describing axial length changes induced by circumferential buckling using solid silicone rubber.

Results

Twenty-eight patients (mean age 49.7 years, range 16–72) met the inclusion criteria. Mean axial length was 25.38 mm preoperatively and 26.12 mm at least 6 months postoperatively (SD 0.50 ± 0.09, p < 0.001); a mean increase of 0.74 mm. Half the patients subsequently underwent cataract surgery. Post-operative changes were not significant compared to pre-surgical refraction and corneal astigmatism. Axial length change was not significant between sexes (9 women and 19 men).

Conclusions

Axial length changes induced by circumferential scleral buckling using silicone sponge exclusively are similar to those reported in the literature for solid silicone rubber buckles. Scleral buckling using a silicone sponge, which may offer several surgical advantages, induces an acceptable axial length change similar to that seen with widely-used solid silicone rubber buckles.

Background

Although its popularity has declined in recent years [1], scleral buckling is still commonly used for the treatment of rhegmatogenous retinal detachment, either as a stand-alone procedure or combined with vitrectomy. Scleral buckling has several drawbacks and unique side effects, including conjunctival scarring, explant exposure or infection, diplopia (usually transient), globe penetration while suturing the explants to the sclera, and others [2,3,4,5,6]. Axial length change, one of the most common side effects of scleral buckling surgery, is caused by the buckle deforming and indenting the globe, which causes a refractive shift. This common side effect is particularly bothersome in previously emmetropic patients, in patients previously isometropic in whom it may induce anisometropia, and in previously emmetropic pseudophakic patients, who are frustrated by the need for refractive correction in a previously ametropic eye after cataract surgery.

Scleral buckling using solid silicone rubber explants is the most widely used form of buckling surgery, and several publications have documented the axial length changes it induces [7,8,9,10,11,12,13,14,15,16,17,18]. Our department uses only silicone sponge explants, rather than the solid silicone rubber explants used in most institutions. To the best of our knowledge, axial length changes induced exclusively by using silicone sponge buckles have not been well documented. In this study, we sought to determine whether the change in axial length induced by silicone sponge circular explants was significantly different from that reported in the literature for solid silicone explants, and whether one explant material was more advantageous than the other was.

Methods

Records of all patients who underwent scleral buckling surgery in our department during 2009–2013 by two vitreoretinal senior surgeons (Y.F. and A.R.) using circumferential 7.5 mm × 2.5 mm silicone sponge explants (Labtician Ophthalmics, Style 511, Oakville, ON, CA) were reviewed. Scleral sutures were placed at 9 mm width (1.5 mm wider than the sponge), using 5–0 Ethilon (Ethicon US, Somerville NJ, USA) scleral mattress sutures to provide an indentation effect.

Only patients with a successfully attached retina at least six months after surgery, whose charts contained reliable preoperative axial length measurements using the Zeiss IOL Master (Carl Zeiss Meditech, Jena, Germany), without intravitreal silicone oil (which would preclude reliable axial length measurement), and who had circumferential explants placed without additional radial buckling elements were included. Patients with these characteristics were called and invited to participate in the study. Those who chose to participate received an explanation of the study goals and signed an informed consent. Subsequently, they underwent at least three repeated IOL-Master biometry axial length measurements, the axial length measurements were performed by two ophthalmologists (S.S.O. and A.F.)

The charts were reviewed for surgical details, preoperative phakic status, and demographic data such as age and sex. The pre- and post-operative biometrics were compared using paired t test. p < 0.05 was considered statistically significant. Statistical analyses were performed using SPSS, Inc., version 21.

As approximately half the patients were phakic at the time of their detachment surgery and later had cataract surgery, their refractive status was influenced by differing techniques and intraocular lens types and was therefore not included in the analysis.

The literature was reviewed for articles describing axial length changes caused by circumferential scleral buckling with solid silicone rubber explants or silicone sponge explants, including articles in all languages from 1970 to the present.

Results

Twenty-eight eyes of 28 patients met the inclusion criteria. Mean age was 49.7 years (range 16–72 years). The mean axial length was 25.38 mm preoperatively, and 26.12 mm at least 6 months postoperatively (SD 0.497 ± 0.094, p < 0.001), a mean increase of 0.74 mm (Table 1).

Table 1 Pre- and postoperative measurements of 28 eyes

Refraction did not change significantly after surgery (−2.78D before to −3.49 after, SD 2.58 ± 0.58, p = 0.156, respectively). Axial length change between sexes was not significant (9 women and 19 men). However, more males underwent surgery.

Corneal astigmatism did not change significantly after surgery (−1.03D to −1.39D respectively, SD 0.75 ± 0.14, p = 0.17).

Discussion

Axial length change is a common side effect of scleral buckling surgery. It is caused by the buckle causing an indentation in the globe, which might cause a refractive shift. Our ophthalmology department uses soft, pliable, silicone sponge buckles, as we feel they induce a more gradual and rounded indentation of the globe wall than that seen with solid silicone buckling. We compared this method with the use of solid silicone reported in the literature.

Although numerous articles describe axial length changes after scleral buckling surgery [7,8,9,10,11,12,13,14,15,16,17], the surgeries and methods used, as well as patient characteristics, length of follow-up and measurements reported vary widely. This makes it difficult to establish a standard, acceptable axial length change with the commonly used method of solid silicone rubber buckling, and complicates comparison with the buckling method used in our institution.

Some reports regarding axial length change after scleral buckling used the older method of intra-scleral implants rather than the explants used today [8,9,10, 14]. Others included several methods in undisclosed proportions or various surgical methods that were not described [8, 9, 15, 16, 18], also precluding meaningful comparison.

Sato et al. [14] included only pediatric eyes. This causes additional comparison problems due to the possibility of differing effects of buckling on globe growth and scleral compliance at various ages. Additionally, one article included buckle height measurements but not axial length [9], while others measured axial lengths after very short or varying and unspecified periods of follow-up [10, 17], where the eyes may not have reached their final axial length. Most of these articles included several of the above mentioned limitations.

Previously published articles used A-scan ultrasound to measure axial length, whereas we used optical biometry with the Zeiss IOL-Master. Optical biometry has been shown to yield extremely accurate and reliable axial length measurements, and measurements obtained with these two methods agree closely and are interchangeable [19,20,21,22,23].

The few remaining articles, where exclusively solid silicone buckles and elements were used as explants, with methods described in detail, adequate follow-up and axial length measurements were used as a comparison to our buckling method. Larsen and Syrdalen [11] found that the average axial length increased 0.98 mm in 10 eyes, Brazitikos et al. [7] reported a mean axial length increase of 0.95 mm in 75 eyes and Malukiewicz-Wisniewska and Stafiej [12] showed a mean increase at one year of 0.57 mm in all 74 eyes. As can be seen in the relevant articles, the mean axial length increased from 0.57 mm to 0.98 mm after scleral buckling surgery.

Conclusion

We found a mean axial length increase of 0.74 mm at least 6 months after surgery. This is comparable (although possibly closer to the lower end) to that previously described for scleral buckling with solid silicone elements.

We did not find any reports describing axial length changes after scleral explant surgery using a silicone sponge. Although, several papers described axial length changes with combined solid silicone and silicone sponge elements.

In this study, we have shown that axial length changes six months after scleral explant surgery using a silicone sponge are comparable to those described in the literature after solid silicone rubber buckling.

References

  1. Chong DY, Fuller DG. The declining use of scleral buckling with vitrectomy for primary retinal detachments. Arch Ophthalmol. 2010;128:1206–7.

    Article  PubMed  Google Scholar 

  2. Brucker AJ, Hopkins TB. Retinal detachment surgery: the latest in current management. Retina. 2006;26:S28–33.

    PubMed  Google Scholar 

  3. Charonis A, Chang TS. Anterior segment complications associated with scleral buckling. Ophthalmol Clin North Am. 2004;17:545–56.

    Article  PubMed  Google Scholar 

  4. Chaudhry NL, Durnian JM. Post-vitreoretinal surgery strabismus—a review. Strabismus. 2012;20:26–30.

    Article  CAS  PubMed  Google Scholar 

  5. Schwartz SG, Flynn HW Jr, Mieler WF. Update on retinal detachment surgery. Curr Opin Ophthalmol. 2013;24:255–61.

    Article  PubMed  Google Scholar 

  6. Tsui I. Scleral buckle removal: indications and outcomes. Surv Ophthalmol. 2012;57:253–63.

    Article  PubMed  Google Scholar 

  7. Brazitikos PD, Androudi S, Christen WG, Stangos NT. Primary pars plana vitrectomy versus scleral buckle surgery for the treatment of pseudophakic retinal detachment: a randomized clinical trial. Retina. 2005;25:957–64.

    Article  PubMed  Google Scholar 

  8. Burton TC, Herron BE, Ossoinig KC. Axial length changes after retinal detachment surgery. Am J Ophthalmol. 1977;83:59–62.

    Article  CAS  PubMed  Google Scholar 

  9. Gopal L, D’Souza C, Bhende M, Fogla S, Ratra D, Shetty NS, et al. Scleral buckling-implant versus explant. Retina. 2003;23:636–40.

    Article  PubMed  Google Scholar 

  10. Kiernan JP, Leveille AS, Morse PH. Axial length following scleral buckling. Retina. 1982;2:176–8.

    Article  CAS  PubMed  Google Scholar 

  11. Larsen JS, Syrdalen P. Ultrasonographic study on changes in axial eye dimensions after encircling procedure in retinal detachment surgery. Acta Ophthalmol (Copenh). 1979;57:337–43.

    Article  CAS  Google Scholar 

  12. Malukiewicz-Wisniewska G, Stafiej J. Changes in axial length after retinal detachment surgery. Eur J Ophthalmol. 1999;9:115–9.

    Google Scholar 

  13. Okada Y, Nakamura S, Kubo E, Oishi N, Takahashi Y, Akagi Y. Analysis of changes in corneal shape and refraction following sclera buckling surgery. Jpn J Ophthalmol. 2000;44:132–8.

    Article  CAS  PubMed  Google Scholar 

  14. Sato T, Kawasaki T, Okuyama M, Ideta H. Refractive changes following scleral buckling surgery in juvenile retinal detachment. Retina. 2003;23:629–35.

    Article  PubMed  Google Scholar 

  15. Smiddy WE, Loupe DN. MIchels RG, Enger C, Glaser BM, deBustros S. Refractive changes after scleral buckling surgery. Arch Ophthal. 1989;107:1469–71.

    Article  CAS  PubMed  Google Scholar 

  16. Tanihara H, Negi A, Kawano S, Ishigouoka H, Ueda Y, Yoshida-Suzuki S, Amano H, Satou E, Honda Y. Axial length of eyes with rhegmatogenous retinal detachment. Ophthalmologica. 1993;206:76–82.

    Article  CAS  PubMed  Google Scholar 

  17. Vukojević N, Sikić J, Curković T, Juratovac Z, Katusić D, Sarić B, Jukić T. Axial eye length after retinal detachment surgery. Coll Antropol. 2005;29(Suppl 1):25–7.

    PubMed  Google Scholar 

  18. Wang HZ, Chen MT, Chang CH, Tsai MC, Wu WC, Chung CB. The changes of ocular axial length and corneal curvatures after sclera buckling for retinal detachment. Gaoxiong Yi Xue Ke Xue Za Zhi. 1994;10:77–83.

    CAS  PubMed  Google Scholar 

  19. Bjeloš Rončević M, Bušić M, Cima I, Kuzmanović Elabjer B, Bosnar D, Miletić D. Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation. Graefes Arch Clin Exp Ophthalmol. 2011;249:69–75.

    Article  PubMed  Google Scholar 

  20. Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238:765–73.

    Article  CAS  PubMed  Google Scholar 

  21. Hussin HM, Spry PG, Majid MA, Gouws P. Reliability and validity of the partial coherence interferometry for measurement of ocular axial length in children. Eye (Lond). 2006;20:1021–4.

    Article  CAS  Google Scholar 

  22. Packer M, Fine IH, Hoffman RS, Coffman PG, Brown LK. Immersion A-scan compared with partial coherence interferometry: outcomes analysis. J Cataract Refract Surg. 2002;28:239–42.

    Article  PubMed  Google Scholar 

  23. Rajan MS, Keilhorn I, Bell JA. Partial coherence laser interferometry vs. conventional ultrasound biometry in intraocular lens power calculations. Eye (Lond). 2002;16:552–6.

    Article  CAS  Google Scholar 

Download references

Authors’ contributions

SSO: Responsible for study conception and design, drafted the manuscript and revised it critically for important intellectual content, gave final approval of the version to be published; and agrees to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. AR: Acquisition of data and analysis and interpretation of data, gave final approval of the version of the submitted manuscript and agrees to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. AF: Responsible for study conception and design of and interpretation of data, revised the draft manuscript and agrees to be accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. All authors read and approved the final manuscript.

Acknowledgements

Faye Schreiber, MS edited the manuscript.

Competing interests

The authors have no competing interests to declare.

Availability of data and supporting materials

The deidentified data will be made available on request.

Ethics approval and consent to participate

The study was approved by the Meir Medical Center Ethics Committee on June 11, 2013, file number 012512. All participants provided signed informed consent.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexander Rubowitz.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ophir, S.S., Friehmann, A. & Rubowitz, A. Circumferential silicone sponge scleral buckling induced axial length changes: case series and comparison to literature. Int J Retin Vitr 3, 10 (2017). https://doi.org/10.1186/s40942-017-0063-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40942-017-0063-1

Keywords