A Pre-operative color photo of the fundus of the right eye of a 14-year-old boy with traumatic FTMH. Note the sheer size of the hole, which was approximately ¾ disc diameter, the yellowish pigmentation in the base of the hole, and the sub-retinal cuff of fluid. B OCT image of the macula in a radial scan mode. Note the pregnant draw-bridge configuration of the edges of the hole (asterisks). MLD was 1068 µm. The base diameter was 2259 µm. BCVA was 0.05. C Post-operative line scan of the macula after 2 months of follow-up. Note the ILM plug (white arrow), and the U-type closure of the hole. BCVA was 0.1. D Microperimetry of the right macular area revealed unstable fixation (Fujii classification) and high BCEA values indicating poor macular sensitivity and fixation. Note the dense central scotoma in the color-coded map