Skip to main content

Table 3 Subgroup analysis (p-value)

From: Performance, safety and efficiency comparison between 10,000 and 5000 cuts per minute vitrectomy using a 25G cutter: a prospective randomized controlled study

 

Vitreous hemorrhage

Macular hole

Epiretinal membrane

Retinal detachment

Macular hole

0.9948

   

Epiretinal membrane

0.4585

0.9839

  

Retinal detachment

0.0349*

0.2442

0.0002*

 

Dislocated IOL

0.9711

0.9998

0.9980

0.1595

  1. Subgroup multiple comparison by one way ANOVA & Tukey’s test, *Significance p < 0.05