Skip to main content

Intrusion of episcleral buckles: report of two cases and brief review

Abstract

Background

The authors report two cases of the scleral buckles intrusion and erosion that presented many years after primary surgery with vitreous haemorrhage in one of them. Although the erosion/intrusion of a silicone scleral buckleĀ (SB) is rare, it may have serious consequences and optimal management can be challenging. Therefore, this diagnosis should be considered if attributable signs and symptoms including vitreous haemorrhage occurred after scleral buckling. The authors briefly review the literature on clinical presentation and management of the episcleral silicone buckling erosion and intrusion.

Case presentation

Case 1: A 48-year-old woman with a history of scleral buckling for an inferior rhegmatogenous retinal detachment presented with visual loss in her right eye. A vitreous haemorrhage was observed. After Close observation, Partial resolution of haemorrhage revealed an intruded sponge segment in inferior vitreous cavity. Case 2: A 26-year-old man was referred for retinal evaluation. Twenty years earlier, he had undergone lensectomy for bilateral childhood cataract. Ten years ago, he had developed an aphakic RRD in the left eye. The detachment was managed with pars plana deep vitrectomy, endolaser, an encircling silicone band, and silicone oil injection. On examination an eroded band was noted.

Conclusion

Although the erosion/intrusion of a silicone episcleral buckle is rare, it may have serious consequences and optimal management can be challenging. Unnecessarily destructive techniques may predispose the eye to this complication and should be avoided. Patients who have a history of SB need lifelong follow-up and this diagnosis should be considered if attributable signs and symptoms occurred.

Background

Extrusion, erosion, and intrusion of buckling elements are rare but important complications of scleral buckling (SB) [1, 2]. Extrusion is the penetration of buckling element through Tenonā€™s capsule and conjunctiva externally. Erosion occurs when the element migrates internally and rests in subretinal space. Protrusion of the element into the vitreous cavity is called intrusion [2,3,4]. Suggested predisposing factors for intrusion includes myopia, glaucoma, thin sclera, multiple operations and infection [1, 3]. Scleral buckling erosion/intrusion may lead to retinal redetachment, pigment dispersion, vitreous haemorrhage, epithelial ingrowth, and endophthalmitis [4]. Here, we report two cases of erosion/intrusion of scleral buckles and review the literature.

Case presentation

Case 1

A 48-year-old woman presented with visual loss in her right eye. She reported similar episodes of transient visual obscuration in the same eye in recent 2Ā years with spontaneous resolution. Best corrected visual acuity (BCVA) was 20/200 in the right eye and 20/20 in the left eye. In the right eye, a vitreous haemorrhage blocking the fundus view was observed. Echography revealed an attached retina. The same eye had undergone cataract surgery and SB surgery, three and 29Ā years earlier, respectively. According to her surgical records, SBĀ had been performed for an inferior rhegmatogenous retinal detachment (RRD): ā€œafter localizing, cryopexy was applied and a sponge segment was placed on the hole. Tire and band were passed beneath the muscles and fixed to the sclera by Mersilene sutures. Drainage of subretinal fluid was done via a 3Ā mm long sclerotomy which subsequently was closed with a mattress suture and treated with cryopexyā€.

Close observation was scheduled. Partial resolution of haemorrhage revealed an intruded sponge segment in inferior vitreous cavity (Fig.Ā 1a). To further clarify the pathology an orbital computed tomography was done (Fig.Ā 1b). Fluorescein angiography was performed to rule out other causes of vitreous haemorrhage (Fig.Ā 1c). To stabilize the retina as much as possible in case that buckle removal was needed, additional barrier laser was done. In following 16Ā months, despite multiple telephone recalls, patient did not comeback for followup visits. However, she reported good vision and no recurrence of symptoms.

Fig.Ā 1
figure 1

Case 1: a An intruded silicone sponge, partially covered with blood is seen in inferior vitreous cavity. Adjacent retina and choroid show extensive pigmentary and atrophic changes. b In sagittal orbital computed tomography (CT) scan, intruded hypodense silicone sponge is seen over the hyper dense silicone rubber (tire and band complex) in inferior globe. c Fluorescein angiography shows an extensive hypofluorescent area caused by severe chorioretinal atrophy in inferior retina

Case 2

An asymptomatic 26-year-old man was referred for retinal evaluation. Twenty years earlier, he had undergone lensectomy for bilateral childhood cataract. Ten years later he had developed an aphakic RRD in the left eye. The detachment was managed with placement of an encircling silicone band (band 240) 10ā€“13Ā mm posterior to limbus, same session three port 20-gauge pars plana deep vitrectomy, 360Ā° endolaser, and silicone oil injection. Three months later, silicone oil was removed following additional external laser photocoagulation. On examination, left eye had a BCVA of 20/28 and retina was attached. An eroded band was noted (Fig.Ā 2). To address the possibility of progressive intrusion, 360Ā° laser was applied posterior to the band. A segment of the band was then cut out surgically via an ab externo approach in supranasal quadrant. In 14Ā months of follow-up, retina remained attached and no changes in funduscopic appearance was noted.

Fig.Ā 2
figure 2

Case 2: Montage fundus photograph of the left eye. The band is seen to erode internally especially in temporal and inferior quadrants

Discussion and conclusions

In early decades following introduction of SB surgery, erosion or intrusion of buckling elements into the eye were much more common. This complication was common when polyethylene tubes, Arruga sutures, and intrascleral silicone implant were used for scleral buckling which nowadays all can be considered obsolete [1]. The incidence of erosion/intrusion of buckling elements has decreased substantially since episcleral silicone sponges and rubber elements became the most common materials for the SB [5].

Here we reported two cases of erosion/intrusion of episcleral silicone buckling elements.

To better delineate predisposing factors, manifestations, and management, we reviewed reported cases of erosion/intrusion of ā€œepiscleral silicone buckling elementsā€ in the literature [1, 3, 6,7,8,9,10,11,12,13] (TableĀ 1). It is noteworthy that none of our cases have evidence of intrusion of anchoring sutures used in SB, therefore we are not discussing this type of complication which has been previously covered comprehensively elsewhere.

TableĀ 1 Summary of reported cases with erosion/intrusion of episcleral buckles

The mean interval time (from SB to erosion/intrusion) in reported cases is 10.88ā€‰Ā±ā€‰8.61Ā years (rangeā€‰=ā€‰0.25ā€“29Ā years). This wide range may reflect variations in scleral thickness and resistance and variations in surgical details of SB procedures (e.g. cryopexy, diathermy, drainage of subretinal fluid and degree of tightening of the encircling elements) [14]. However, majority of cases are discovered more than 10Ā years after SB [5].

Eleven out of twelve patients were treated with a cerclage (with or without segmental elements): ten had an encircling band and one had an encircling sponge. It seems that prolonged circumferential inward force from a tight cerclage is a major contributing factor.

Six patients had an encircling band combined with a segmental sponge (four cases) or a tire (two cases). A rubber tire is wider than a rubber band. Therefore, compared to a tightened band alone, force exerted by a tightened band on a tire is distributed over a larger area of sclera. This mechanism leads to decreased pressure over the underlying sclera and may be protective against erosion/intrusion [6]. Interestingly, in one of two reported cases with encircling band and a segmental tire, the intruded element has been the band in the ā€œopposite quadrantā€ of the segmental tire [12]. Second reported case of combined encircling band and tire is case 1 of our report, who had reminiscences of excessive surgical interventions: placing a segmental sponge over the break after cryopexy, cryopexy and suturing of the drainage site, and using encircling tire and band over the sponge. Widespread atrophic changes in fluorescein angiography in this case (Fig.Ā 1c) also suggests excessive cryopexy. This suggests that in cases of compromised scleral resistance- either as a preexisting condition or as a consequence of destructive surgical interventions-the tire may not be enough to protect the sclera from pressure of a tightened encircling band.

Using diathermy or cryopexy has been documented in five patients [9, 11, 13] (TableĀ 1). As mentioned earlier, our first case showed evidence of excessive treatment including intense cryopexy which may weaken the sclera.

It has been suggested that if the drainage sclerotomy under the buckling element is to be closed with sutures, absorbable sutures are preferred to nonabsorbable sutures [10]. According to surgical records of our case 1, drainage sclerotomy had been closed with a mattress suture, however, the nature of this suture was not mentioned.

A history of multiple ocular operations may be considered an additional risk factor for buckle erosion in our case 2.

The optimal management of scleral buckle erosion/intrusion should be tailored to each case. Severity, extent, symptoms and course of erosion/intrusion should be considered. As shown in TableĀ 1, five patients were planned to be under observation initially. However, progression of intrusion is reported in two of them eventually [1, 9].

In our first case the vitreous haemorrhage resolved gradually and after applying peripheral laser, patient reported no recurring symptoms in the next 16Ā months.

Cutting of the band with or without total or segmental removal of buckling elements has been suggested for the management [12]. However, the benefits of these methods remains unproven [8, 9, 12]. In some cases, observation is warranted. One concern is that removing the intruded buckling element may leave the globe open; if the removal is planned, surgeon should be prepared to manage any possible scleral defect.

Although the erosion/intrusion of a silicone episcleral buckle is rare, it may have serious consequences and optimal management can be challenging. Unnecessarily destructive techniques may predispose the eye to this complication and should be avoided. Patients who have a history of SB need lifelong follow-up and this diagnosis should be considered if attributable signs and symptoms occurred.

Availability of data and materials

Not applicable. This is a case report.

Abbreviations

SB:

Scleral buckling

RRD:

Rhegmatogenous retinal detachment

References

  1. Nguyen QD, Lashkari K, Hirose T, Pruett RC, McMeel JW, Schepens CL. Erosion and intrusion of silicone rubber scleral buckle. Presentation and management. Retina. 2001;21(3):214ā€“20.

    ArticleĀ  CASĀ  Google ScholarĀ 

  2. Schepens CL, Okamura ID, Brockhurst RJ. The scleral buckling procedures. I. Surgical techniques and management. AMA Archiv Ophthalmol. 1957;58(6):797ā€“811.

    ArticleĀ  CASĀ  Google ScholarĀ 

  3. Unlu N, Kocaoglan H, Acar MA, Aslan BS, Duman S. Intraocular intrusion of a scleral sponge implant. Ophthalmic Surg Lasers Imaging. 2003;34(3):223ā€“5.

    ArticleĀ  Google ScholarĀ 

  4. Kumar N, Zeldovich A, Chang A. Clinical case notes. Clin Exp Ophthalmol. 2004;32(2):228ā€“9.

    ArticleĀ  Google ScholarĀ 

  5. Chronopoulos A, Schutz J, Varga Z, Souteyrand G, Thumann G. Complications of encircling bands-prevention and management. J Clin Exp Ophthalmol. 2015;6(440):2.

    Google ScholarĀ 

  6. Deramo VA, Haupert CL, Fekrat S, Postel EA. Hypotony caused by scleral buckle erosion in Marfan syndrome. Am J Ophthalmol. 2001;132(3):429ā€“31.

    ArticleĀ  CASĀ  Google ScholarĀ 

  7. Mitra A, Sen A, Agrawal T, Kohli G. Intraocular intrusion in vitreous cavity of encirclage band following retinal detachment surgery. Indian J Ophthalmol. 2018;66(11):1625ā€“6.

    ArticleĀ  Google ScholarĀ 

  8. Shami MJ, Abdul-Rahim AS. Intrusion of a scleral buckle: a late complication of retinal reattachment surgery. Retina. 2001;21(2):195ā€“7.

    ArticleĀ  CASĀ  Google ScholarĀ 

  9. Birgul T, Vidic B, El-Shabrawi Y. Intrusion of an encircling buckle after retinal detachment surgery. Am J Ophthalmol. 2003;136(5):942ā€“4.

    ArticleĀ  Google ScholarĀ 

  10. Gu R, Chen X, Song F, Jiang C, Zhu H, Xu G. Intrusion of Dacron suture knot 15Ā years after scleral buckling. BMC Ophthalmol. 2018;18(1):327.

    ArticleĀ  Google ScholarĀ 

  11. Liang SY, Lee LR. Management of a silicone sponge explant eroding through the scleral wall. Clin Exp Optom. 2009;92(6):505ā€“6.

    ArticleĀ  Google ScholarĀ 

  12. Shetty S, Bhende M. Managing a case of buckle intrusion with recurrent vitreous haemorrhage: a case report. Med Vis Res Found. 2017;35(2):37ā€“40.

    Google ScholarĀ 

  13. Garay-Aramburu G, Larrauri-Arana A. A scleral buckle intrusion 19Ā years after its use in retinal detachment surgery. Archiv Soc Esp Oftalmol. 2007;82(7):443ā€“5.

    ArticleĀ  CASĀ  Google ScholarĀ 

  14. Hatori T, Imai M, Iijima H. Intravitreal intrusion of an intrascleral MIRAgel buckling implant. Jpn J Ophthalmol. 2011;55(3):310ā€“1.

    ArticleĀ  Google ScholarĀ 

Download references

Acknowledgements

Not applicable.

Funding

All the sources were provided by the authors.

Author information

Authors and Affiliations

Authors

Contributions

All authors: data collection, manuscript preparation, critical revision of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Hamid Riazi-Esfahani.

Ethics declarations

Ethics approval and consent to participate

Both patients provided written informed consent and study was performed with the approval of the Institutional Review Board and ethics committee of Tehran University of Medical Science and complied with the guidelines of the Declaration of Helsinki.

Consent for publication

Written informed consent was obtained from the patients for publication of this Case report and any accompanying images.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zarei, M., Mahmoudi, A., Hadi, A. et al. Intrusion of episcleral buckles: report of two cases and brief review. Int J Retin Vitr 6, 7 (2020). https://doi.org/10.1186/s40942-020-00210-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40942-020-00210-7

Keywords